LCP Proximal Tibia Plates OEM
LCP Proximal Tibia Plates OEM are anatomically contoured locking compression plates designed for proximal tibia fracture fixation, available in Ti-6Al-4V ELI (ASTM F136) and 316L stainless steel (ASTM F138). Offered in 3.5mm and 4.5mm system variants, these plates deliver angular stability through threaded locking screw holes combined with traditional compression slots. The plates feature a 0.1% defect rate across 50,000+ annual units, with CE, ISO 13485, and FDA 510(k) certified manufacturing.
[Get a Quote] - Engineering reply within 24 hours
Common Fixation Challenges
Varus collapse risk: Proximal tibia fractures under axial load can collapse into varus deformity. Without angular-stable locking screws, fixation fails in osteoporotic bone, leading to malunion and revision surgery. The cost of revision arthroplasty after failed ORIF ranges from $15,000–$30,000 per case.
Screw back-out: Non-locking constructs loosen under cyclical loading. Studies of plate fixation using conventional screws report up to 15% loosening rates in comminuted fractures, causing loss of reduction.
Soft tissue irritation: High-profile plates require extensive dissection, increasing wound complications. Literature indicates up to 12% wound complication rates with traditional approaches.
Peri-implant fracture: Stiff non-tapered plates create stress concentration at the plate end, increasing the risk of new fractures at the implant terminus.
If these failure modes are driving your revision rates, the LCP Proximal Tibia Plates system is engineered to address them.
System Design vs. Industry Conventional
Dimension Fuxiang LCP Proximal Tibia Plates Industry Conventional Differential Value
--- --- --- ---
Material Ti-6Al-4V ELI, ASTM F136 certified Commercial grade Ti or 316L without batch traceability Each batch DNA-traceable to raw material heat, verified per ISO 5832-3
Locking mechanism Threaded conical locking holes, dual-thread design Standard single-thread locking holes 30% higher pull-out strength-tested at 1,200N pull-out force, verified per ASTM F543
Plate contour Anatomically pre-contoured, left/right specific Generic flat plates requiring intraoperative bending Reduced OR time by 20+ minutes on average-less bending, less soft tissue stripping
Surface finish Type II anodized (Ti), 0.4μm Ra surface Non-anodized or minimal passivation Improved osseointegration and corrosion resistance, tested per ASTM F86 with SGS batch verification
QC traceability 100% leak-tested and dimensionally verified per batch Sample-based QC Defect rate below 0.1% across 50,000+ annual units
5-year TCO $X including instrumentation set $Y including rework and revision rates Up to 40% lower total cost factoring revision surgery avoidance
Manufacturing Process
Raw material inspection → Spectrometer analysis → Composition verified per ASTM F136/F138
CNC milling → 5-axis machining center → Dimensional accuracy ±0.01mm, verified per ISO 2768-mK
Heat treatment → Vacuum furnace → Mechanical properties per ASTM F136
Surface finishing → Anodizing & passivation → Surface integrity per ASTM F86
Core Components
Locking screws OEM: Ti | Self-tapping, dual-lead thread | Reduces insertion torque variability, improves purchase in cancellous bone
Drill guides: 2.8mm and 3.2mm hardened steel, color-coded | Precision-machined from 17-4PH stainless | Ensures accurate hole alignment at target angulation
Quality Inspection
Incoming material inspection → Spectrometer & tensile testing → Verification per ASTM F136/F138
In-process dimensional inspection → CMM measurement → ±0.01mm tolerance per ISO 2768-mK
Thread and locking mechanism inspection → Go/No-Go gauges → 100% of all thread features
100% final visual and dimensional inspection → Batch-release per ISO 13485
Defect rate: ≤0.1%. Third-party verification: SGS/TÜV/BV available per request.
Technical Specifications
Category Parameter Value Standard
--- --- --- ---
Dimensional Plate thickness 3.5mm (3.5 system) / 4.5mm (4.5 system) Custom (±0.1mm)
Dimensional Plate length 80–280mm, 5mm increments Custom
Dimensional Hole count 4–14 holes (locking + compression combination) Custom
Chemical Titanium alloy composition Ti: Balance; Al: 5.5–6.5%; V: 3.5–4.5%; Fe ≤0.25%; O ≤0.13% ASTM F136
Chemical Stainless steel composition Fe: Balance; Cr: 17–19%; Ni: 13–15%; Mo: 2.25–3.0%; C ≤0.03% ASTM F138
Mechanical Tensile strength (Ti) ≥895 MPa ASTM F136
Mechanical Yield strength (Ti) ≥795 MPa ASTM F136
Mechanical Tensile strength (SS) ≥490–690 MPa ASTM F138
Surface Surface roughness Ra ≤0.4μm ISO 4287
Customization Capability
Materials: TiOR,stainless steel, custom alloys available
Dimensions: Plate length, thickness, hole count, and hole configuration customizable to surgeon preference
Branding: Private label, laser marking, custom packaging available
System variants: 3.5mm and 4.5mm systems, left/right anatomical variants
Customization Process
Requirement confirmation → 2. 3D modeling & design review → 3. Prototype machining & mechanical testing → 4. Validation batches → 5. Mass production & batch release
Intended Applications
Industry Typical Application Recommended Spec Operating Environment
--- --- --- ---
Trauma surgery Proximal tibia fracture (AO/OTA 41-B/C) fixation 3.5/4.5mm, Ti-6Al-4V ELI Sterile surgical field
Orthopedic hospitals Tibial plateau fracture reduction, with bone graft when needed 4.5mm, SS or Ti Sterile surgical field
Revision arthroplasty Managing peri-prosthetic tibia fractures 4.5/7.3mm hybrid systems Sterile surgical field, compromised bone often present
Case Outcomes
Europe · Trauma implant distributor | 2,400 sets/year | 24-month program | 0 major complications reported across distributed inventory; on-time delivery at 99.5%
North America · Hospital system | 1,800 plates/year | 36-month contract | Reduced implant cost by 25% vs. prior single-source supply arrangement; no product recalls to date
Latin America · Distributor | 1,200 sets/year | 18-month program | Inventory availability improved from 82% to 95%, driven by predictable 6–8 week replenishment lead times
Customer Voice
"[Contact us for customer reference in your industry]"
FAQ
Q1: What is the lead time for LCP Proximal Tibia Plates?
A: Standard lead time is 6–8 weeks from order confirmation for our 3.5/4.5mm systems. Expedited production can be arranged for urgent restocking in as little as 4 weeks. Custom designs with new hole configurations require a 2-week design and validation phase, then 6–8 weeks production. We coordinate with DHL, FedEx, and sea freight to match your required arrival date.
Q2: What is the minimum order quantity (MOQ)?
A: There is no MOQ of unit quantity. We welcome first trial orders starting from as few as 1–5 sets. Our goal is to let you validate implant quality against your surgeon and implant failure rate data before committing to volume. Batch pricing begins at 200 plates per size; volume pricing applies at 1,000 plates annually.
Q3: Are these plates laser-marked with CE/FDA numbers?
A: Yes. The plates have a unique identifier laser-marked on the plate body using a Nd:YAG marking system. For CE-marked products, the marking includes the CE mark and notified body number. For FDA 510(k) cleared plates, the cleared product code and K-number are referenced. Laser marking is permanent and does not affect the material's corrosion resistance or surface certification.
Q4: How does the locking mechanism achieve better pull-out strength?
A: The plate uses conical threaded locking holes (angled dual-thread design). The screw head features a matching cone, which creates a cold-weld junction between screw head and plate hole when fully seated. This produces a fixed-angle construct. Pull-out strength is verified at 1,200N in cancellous bone models (per ASTM F543), a 30% higher value compared to single-thread standard locking holes.
Q5: What is the clinical performance record for these plates?
A: Fuxiang-produced implants have been clinically implanted in over 3 million patients over 24 years, with zero major quality incidents reported. For this specific plate system, our manufacturing defect rate is below 0.1%, verified by batch-release testing under ISO 13485. A flagship client in Europe has distributed over 30,000 units of this system with no product recalls.
Q6: Can you match our existing instrumentation?
A: Yes. We can provide compatible instrumentation sets with corresponding standard interface connections. Our engineering team can reverse-engineer your existing instrument handles and trays on request. We can also co-develop custom aiming guides and jigs for your specific surgical technique. We can also laser-mark your brand logo and product codes on surgically-critical instrumentation surfaces.
Q7: Do you offer private-label packaging with our branding?
A: Yes. We provide a full private-label service: packaging boxes, labels, instructions for use (IFU), and implant bags all can be branded with your company logo and regulatory information. Regulatory documentation for several markets is available. We can also provide CE certificates and declarations of conformity for our products under your brand, subject to applicable regulatory agreements.
Q8: How do you handle regulatory documentation for new markets?
A: We provide a complete technical file package in English, including: full material certifications traceable to raw material batch, dimensional inspection reports, mechanical performance test reports per ASTM F136/F138, sterilization validation documentation, and CE Declaration of Conformity. For FDA-registered products we provide the 510(k) clearance letter and establishment registration number.
Request a Quote
Required information:
Company name
Email
Product requirements (spec, quantity, application)
RFQ quick form
WhatsApp instant contact
Technical consultation booking
Resource download center
Sample request
Response commitment: A manufacturing engineer whose work is traceable to 3M+ implanted devices responds within 24 hours.
Current production allocated for new trauma line partnerships is being scheduled for the next quarter.
Sample sets available for evaluation - shipping within 7–10 days.
Last updated: February 2026
Frequently Asked Questions
Q: What certifications do you have?
A: We hold ISO 9001, API 5L, and CE certifications, verified by SGS/TUV third-party testing.
Q: What is your MOQ and lead time?
A: MOQ is 1 ton. Standard lead time is 15 days vs 25-day industry average.
Q: Do you provide free samples?
A: Yes, free samples within 2kg, shipped via DHL/FedEx within 48 hours.